| Merknaam: | XWELL |
| Modelnummer: | Bcds70-05-10 |
| MOQ: | 1 STKS |
| Prijs: | USD 2000/pcs |
| Verpakkingsdetails: | houten kist |
| Betalingsvoorwaarden: | T/T,Western Union,L/C |
100V 10A Charging 20A EV Battery Pack aging machine
ACEY-BT3020-6 is mainly used for charging and discharging cycle test of finished lithium battery packs. The test items includes: battery charging protection voltage, discharge protection voltage, capacity, etc. It has charging, discharging, testing, and circulating 4 test steps. By editing the steps of the plan, the battery can be tested according to the set process.
*Designed for 18650, 26650...lithium battery pack charge and discharge testing and aging after assembling.
*Suitable for: electric bicycle, swing bike, scooter, electric motorcycle, solar energy storage, large capacity energy storage, power tools battery pack
*Charging: Constant current and voltage charging
* Discharge: Constant current discharge
*Checking charging and discharging protection function
*Charging and discharging capacity recording
*Serial port and network connection function
*Computer online monitor, can manage max 254 point
*Store testing data in MYSQL, can review at any time
Product Specification
| Technical Parameter | ||
|
|
Measuring Range | 7-70V |
| Accuracy | ±(0.2% of reading +0.2% of range) | |
|
|
Charging Range | 50-5000mA |
| Charging Accuracy | ±(0.2% of reading +0.2% of range) | |
| Discharge Range | 50-10000mA | |
| Discharge Accuracy | ±(0.2% of reading +0.2% of range) | |
| Charge | Constant Voltage Cut-off Current | Minimum 50mA |
| Capacity | Accuracy | ±1% |
| Power | Discharge Power | ≤700W |
| Time | Inspection Time | Real-time Collection<2S |
| Timing Range | 0-999h/step | |
| Data Recording Interval | ≥5S | |
| Middle Machine Version | 1:1 series | |
| Number of Passages Per Cabinet | 12 channels, four rows and three column | |
|
Charge |
Charging Mode | Constant Current and Constant Voltage Charging |
| Cut-off condition | Voltage, Current, Relative Time, Overcharge Protection | |
| Discharge | Discharge mode | Constant current discharge |
| Cut-off condition | Voltage, Relative Time and Over-discharge Protection | |
| Loop | Cyclic measurement range | 1-999 times |
| Single cycle step number | 100 | |
| Voltage and Current Detection Sampling | Four-wire sampling | |
| Data Base | Using SQL database to manage test data | |
| Upper computer communication mode | Based on TCP/IP Protocol/Serial Port | |
| Data Output Mode | EXCEL/TXT/Chart | |
| Communication Interface | Mesh port | |
| Chassis dimensions | 300x450x170mm | |
| Cabinet size | 900x600x1900mm | |
| Spatial Dimension of Discharge Battery | 900x600x130mm | |